Products / Fire Protection Cladding
Fire Protection Cladding
Panels and tiles that meet European fire standards and the Dutch RWS tunnel fire curve, in absorbing or reflecting builds.
Fire performance
Tested to the RWS Curve
RWS Fire Curve
The Dutch tunnel fire curve, up to 1350°C, the most demanding test a cladding faces in Europe.
European Classes
Reapor A1 s1 d0 and concrete tiles A2 or B s1 d0 to EN 13823; FPCS board to 1350°C on the RWS curve.
Absorbing or Reflecting
Reapor and concrete tiles come in absorbing builds; the FPCS board is reflecting. Fire and noise are solved in one layer.
Four materials
Four Materials Compared
Fire class first, then acoustics, then the sizes the structure needs.
| Material | Fire | Acoustic | Sizes mm | Notes |
|---|---|---|---|---|
| FPCS fire proof board | To 1350°C, RWS curve | Reflecting | 2350 x 1150, 30 thick; 300 kg/m³ | Direct to concrete or in a frame; painted |
| Reapor recycled glass | A1, s1, d0 (EN 13823); RWS curve | A2 to A3, DLα 4 to 12 dB | 625 x 625 or 1250 x 625 | Sprayed in any RAL |
| Absorbing concrete tiles | A2 or B, s1, d0 (EN 13823) | A1 to A4, DLα 6 to 16 dB | 500 x 250 to 6000 x 1500 | Wood fibre, Miscanthus or porous |
| Polycarbonate | NEN 6065 Class 2 | B3 to B4, Rw 26 to 36 dB | To 2000 x 6000; 8 to 15 thick | UV, SR and Margard grades |
Explore by Application
Where fire protection cladding are specified. Each application page covers the typical challenges, decisions and relevant projects.